Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe

The pulsating heat pipe is the advent of avid progression for the rise of heat transfer technology, which in a plethora of modern techniques has risen automatically to the forefront of microelectronics cooling. Recent advances in electronics design and manufacturing resulted in significant increa...

תיאור מלא

שמור ב:
מידע ביבליוגרפי
Main Authors: Yakub, Lt. Md., Murshed, Fahim, Zahir, Samin Shadman
פורמט: Thesis
שפה:אנגלית
יצא לאור: DEPARTMENT OF MECHANICAL ENGINEERING 2021
גישה מקוונת:http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/642
תגים: הוספת תג
אין תגיות, היה/י הראשונ/ה לתייג את הרשומה!
_version_ 1868227048656338944
author Yakub, Lt. Md.
Murshed, Fahim
Zahir, Samin Shadman
author_browse Murshed, Fahim
Yakub, Lt. Md.
Zahir, Samin Shadman
author_facet Yakub, Lt. Md.
Murshed, Fahim
Zahir, Samin Shadman
author_sort Yakub, Lt. Md.
collection DSpace
description The pulsating heat pipe is the advent of avid progression for the rise of heat transfer technology, which in a plethora of modern techniques has risen automatically to the forefront of microelectronics cooling. Recent advances in electronics design and manufacturing resulted in significant increases in heat flux density through miniaturization of components and a simultaneous increase in power requirements associated with increased product functionality. As a result, production of microelectronics cooling devices will be of optimal importance in the face of scientific development. A PHP or pulsating heat pipe is essentially a non-equilibrium heat transfer device whose performance success depends on continuous maintenance of nonequilibrium conditions within the system. A pulsating heat pipe also promises alternatives for the removal of high localized heat fluxes to provide necessary level of temperature uniformity across the components that need to be cooled. The heat is thus transferred not only by latent heat transfer like in other types of heat pipe, but also by the sweeping of the hot walls by colder moving fluid and vice versa. This phenomenon is the reason of high efficiency of PHPs in comparison with other heat pipes. The aim of this research paper is to better understand the operation of PHP through experimental investigation and obtain comparative results with better for different parameters. A series of experiments are conducted on a closed loop PHP with 8 loops of copper capillary tube of 2mm internal diameter. Initially only ethanol was taking as working fluid, later a blend of ethanol and methanol are used as working fluid and the corresponding effects on the process parameters are measured. The operating conditions are the heat input, filling ratio. For both the working fluid, the filling ratios were taken separately, measure of them being 50%,60%,70%,80%. This paper, shall primarily demonstrate the effect of different parameters on the closed looped system and from where the effects of this parameters on the basic heat transfer properties changes in tis value of the content which is the required or specific target of the experiment. Important insights of the operational of CLPHP are obtained and optimum performance and its variation with different working fluid is identified and studied. To conclude, PHP or CLPHP will remain one of the foremost technology for heat transfer at low weight and cost.
format Thesis
id oai:localhost:123456789-642
institution My University
language English
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher DEPARTMENT OF MECHANICAL ENGINEERING
publisherStr DEPARTMENT OF MECHANICAL ENGINEERING
record_format dspace
spelling oai:localhost:123456789-6422021-10-04T04:33:59Z Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe Yakub, Lt. Md. Murshed, Fahim Zahir, Samin Shadman The pulsating heat pipe is the advent of avid progression for the rise of heat transfer technology, which in a plethora of modern techniques has risen automatically to the forefront of microelectronics cooling. Recent advances in electronics design and manufacturing resulted in significant increases in heat flux density through miniaturization of components and a simultaneous increase in power requirements associated with increased product functionality. As a result, production of microelectronics cooling devices will be of optimal importance in the face of scientific development. A PHP or pulsating heat pipe is essentially a non-equilibrium heat transfer device whose performance success depends on continuous maintenance of nonequilibrium conditions within the system. A pulsating heat pipe also promises alternatives for the removal of high localized heat fluxes to provide necessary level of temperature uniformity across the components that need to be cooled. The heat is thus transferred not only by latent heat transfer like in other types of heat pipe, but also by the sweeping of the hot walls by colder moving fluid and vice versa. This phenomenon is the reason of high efficiency of PHPs in comparison with other heat pipes. The aim of this research paper is to better understand the operation of PHP through experimental investigation and obtain comparative results with better for different parameters. A series of experiments are conducted on a closed loop PHP with 8 loops of copper capillary tube of 2mm internal diameter. Initially only ethanol was taking as working fluid, later a blend of ethanol and methanol are used as working fluid and the corresponding effects on the process parameters are measured. The operating conditions are the heat input, filling ratio. For both the working fluid, the filling ratios were taken separately, measure of them being 50%,60%,70%,80%. This paper, shall primarily demonstrate the effect of different parameters on the closed looped system and from where the effects of this parameters on the basic heat transfer properties changes in tis value of the content which is the required or specific target of the experiment. Important insights of the operational of CLPHP are obtained and optimum performance and its variation with different working fluid is identified and studied. To conclude, PHP or CLPHP will remain one of the foremost technology for heat transfer at low weight and cost. 2021-10-04T04:33:56Z 2021-10-04T04:33:56Z 2017-12 Thesis http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/642 en application/pdf DEPARTMENT OF MECHANICAL ENGINEERING
spellingShingle Yakub, Lt. Md.
Murshed, Fahim
Zahir, Samin Shadman
Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title_full Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title_fullStr Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title_full_unstemmed Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title_short Performance Comparison of Fluids in a Closed Loop Pulsating Heat Pipe
title_sort performance comparison of fluids in a closed loop pulsating heat pipe
url http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/642
work_keys_str_mv AT yakubltmd performancecomparisonoffluidsinaclosedlooppulsatingheatpipe
AT murshedfahim performancecomparisonoffluidsinaclosedlooppulsatingheatpipe
AT zahirsaminshadman performancecomparisonoffluidsinaclosedlooppulsatingheatpipe