DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a

Vapor compression refrigeration system was studied as it is the most widely used refrigeration system especially in small scale of refrigeration application such as in domestic application. Performance of the system becomes main issue and many researches are still ongoing to evaluate and improve...

Полное описание

Сохранить в:
Библиографические подробности
Главные авторы: Tazrin, Capt. Afsana, Reni, Sadia Akter, Sium, Navid Md.
Формат: Диссертация
Язык:английский
Опубликовано: DEPARTMENT OF MECHANICAL ENGINEERING 2021
Online-ссылка:http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/640
Метки: Добавить метку
Нет меток, Требуется 1-ая метка записи!
_version_ 1868226983166476288
author Tazrin, Capt. Afsana
Reni, Sadia Akter
Sium, Navid Md.
author_browse Reni, Sadia Akter
Sium, Navid Md.
Tazrin, Capt. Afsana
author_facet Tazrin, Capt. Afsana
Reni, Sadia Akter
Sium, Navid Md.
author_sort Tazrin, Capt. Afsana
collection DSpace
description Vapor compression refrigeration system was studied as it is the most widely used refrigeration system especially in small scale of refrigeration application such as in domestic application. Performance of the system becomes main issue and many researches are still ongoing to evaluate and improve efficiency of the system. In this modern age, various refrigerants are used like R-12, R-22,R-134a etc. All these refrigerants are of CFC/HCFC group. These refrigerants contain high Global Warming Potential (GWP) and Ozone Depletion Potential (ODP). It has become a crying need to use such a refrigerant that is highly efficient as well as environment friendly. We have chosen Liquefied Petroleum Gas as our experimental object. We have investigated the result of an experimental study carried out to determine the performance of domestic refrigerator when a liquefied petroleum gas (LPG) which is locally available which comprises of 80% propane, 20% butane which is varied from company to company is used as a Refrigerant. The LPG is cheaper and possesses an environmental friendly nature with no Ozone Depletion Potential (ODP) and no Global Warming Potential (GDP). It is used in world for cooking purposes. The refrigerator used in the present study is designed to work on LPG. The performance parameters investigated is the refrigeration effect in certain time. The refrigerator worked efficiently when LPG was used as a refrigerant instead of R134a. The evaporator temperature reached -2.2ᵒC with an ambient temperature of 28ᵒC. Also from the experiment which done in atmospheric condition, we can predict the optimum value of cooling effect with the suitable operating condition of regulating valve and capillary tube of the system.
format Thesis
id oai:localhost:123456789-640
institution My University
language English
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher DEPARTMENT OF MECHANICAL ENGINEERING
publisherStr DEPARTMENT OF MECHANICAL ENGINEERING
record_format dspace
spelling oai:localhost:123456789-6402021-10-04T04:20:21Z DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a Tazrin, Capt. Afsana Reni, Sadia Akter Sium, Navid Md. Vapor compression refrigeration system was studied as it is the most widely used refrigeration system especially in small scale of refrigeration application such as in domestic application. Performance of the system becomes main issue and many researches are still ongoing to evaluate and improve efficiency of the system. In this modern age, various refrigerants are used like R-12, R-22,R-134a etc. All these refrigerants are of CFC/HCFC group. These refrigerants contain high Global Warming Potential (GWP) and Ozone Depletion Potential (ODP). It has become a crying need to use such a refrigerant that is highly efficient as well as environment friendly. We have chosen Liquefied Petroleum Gas as our experimental object. We have investigated the result of an experimental study carried out to determine the performance of domestic refrigerator when a liquefied petroleum gas (LPG) which is locally available which comprises of 80% propane, 20% butane which is varied from company to company is used as a Refrigerant. The LPG is cheaper and possesses an environmental friendly nature with no Ozone Depletion Potential (ODP) and no Global Warming Potential (GDP). It is used in world for cooking purposes. The refrigerator used in the present study is designed to work on LPG. The performance parameters investigated is the refrigeration effect in certain time. The refrigerator worked efficiently when LPG was used as a refrigerant instead of R134a. The evaporator temperature reached -2.2ᵒC with an ambient temperature of 28ᵒC. Also from the experiment which done in atmospheric condition, we can predict the optimum value of cooling effect with the suitable operating condition of regulating valve and capillary tube of the system. 2021-10-04T04:20:20Z 2021-10-04T04:20:20Z 2017-12 Thesis http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/640 en application/pdf DEPARTMENT OF MECHANICAL ENGINEERING
spellingShingle Tazrin, Capt. Afsana
Reni, Sadia Akter
Sium, Navid Md.
DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title_full DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title_fullStr DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title_full_unstemmed DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title_short DETERMINATION OF CO-EFFICIENT OF PERFORMANCE (COP) OF A VAPOR COMPRESSION REFRIGERATION CYCLE USING LIQUEFIED PETROLEUM GAS (R-290) AS REFRIGERANT AND COMPARE IT WITH R-134a
title_sort determination of co efficient of performance cop of a vapor compression refrigeration cycle using liquefied petroleum gas r 290 as refrigerant and compare it with r 134a
url http://dspace.mist.ac.bd:8080/xmlui/handle/123456789/640
work_keys_str_mv AT tazrincaptafsana determinationofcoefficientofperformancecopofavaporcompressionrefrigerationcycleusingliquefiedpetroleumgasr290asrefrigerantandcompareitwithr134a
AT renisadiaakter determinationofcoefficientofperformancecopofavaporcompressionrefrigerationcycleusingliquefiedpetroleumgasr290asrefrigerantandcompareitwithr134a
AT siumnavidmd determinationofcoefficientofperformancecopofavaporcompressionrefrigerationcycleusingliquefiedpetroleumgasr290asrefrigerantandcompareitwithr134a