DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2

At first we are thankful to the Almighty, for His blessings and for giving us the courage and enthusiasm accompanied by which we have completed the thesis successfully in due time. We specially thank and express our profound gratitude to our respected thesis supervisor, Prof Dr. Dipak Kanti Das f...

Deskribapen osoa

Gorde:
Xehetasun bibliografikoak
Egile Nagusiak: Noman, Mashruf Ahmad, Rafique, Maimuna Torsa, Toma, Prionkari Banik
Formatua: Tesis
Hizkuntza:ingelesa
Argitaratua: DEPARTMENT OF MECHANICAL ENGINEERING MILITARY INSTITUTE OF SCIENCE AND TECHNOLOGY MIRPUR CANTONMENT, DHAKA - 1216, BANGLADESH 2019
Sarrera elektronikoa:http://hdl.handle.net/123456789/430
Etiketak: Etiketa erantsi
Etiketarik gabe, Izan zaitez lehena erregistro honi etiketa jartzen!
_version_ 1868227028150386688
author Noman, Mashruf Ahmad
Rafique, Maimuna Torsa
Toma, Prionkari Banik
author_browse Noman, Mashruf Ahmad
Rafique, Maimuna Torsa
Toma, Prionkari Banik
author_facet Noman, Mashruf Ahmad
Rafique, Maimuna Torsa
Toma, Prionkari Banik
author_sort Noman, Mashruf Ahmad
collection DSpace
description At first we are thankful to the Almighty, for His blessings and for giving us the courage and enthusiasm accompanied by which we have completed the thesis successfully in due time. We specially thank and express our profound gratitude to our respected thesis supervisor, Prof Dr. Dipak Kanti Das for his constant & meticulous supervision, valuable suggestions and encouragement to carry out this thesis. With due respect, we are also grateful to our respected dean Brig Gen Md. Lutfor Rahman, EME as well as Lt Col Golam Saklayen, EME and Lt Cdr K M R Sadi, (E), BN. We express indebtedness to Shimanto Square authority, Bashundhara Group authority and Bangladesh Bank authority. Finally we would like to thank everybody who supported us in any respect for the completion of the thesis. It has been a marvelous experience to work with such an esteemed faculty to carry out this thesis under one of the most reputable engineering institution of Bangladesh.
format Thesis
id oai:localhost:123456789-430
institution My University
language English
publishDate 2019
publishDateRange 2019
publishDateSort 2019
publisher DEPARTMENT OF MECHANICAL ENGINEERING MILITARY INSTITUTE OF SCIENCE AND TECHNOLOGY MIRPUR CANTONMENT, DHAKA - 1216, BANGLADESH
publisherStr DEPARTMENT OF MECHANICAL ENGINEERING MILITARY INSTITUTE OF SCIENCE AND TECHNOLOGY MIRPUR CANTONMENT, DHAKA - 1216, BANGLADESH
record_format dspace
spelling oai:localhost:123456789-4302019-03-13T04:21:07Z DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2 Noman, Mashruf Ahmad Rafique, Maimuna Torsa Toma, Prionkari Banik At first we are thankful to the Almighty, for His blessings and for giving us the courage and enthusiasm accompanied by which we have completed the thesis successfully in due time. We specially thank and express our profound gratitude to our respected thesis supervisor, Prof Dr. Dipak Kanti Das for his constant & meticulous supervision, valuable suggestions and encouragement to carry out this thesis. With due respect, we are also grateful to our respected dean Brig Gen Md. Lutfor Rahman, EME as well as Lt Col Golam Saklayen, EME and Lt Cdr K M R Sadi, (E), BN. We express indebtedness to Shimanto Square authority, Bashundhara Group authority and Bangladesh Bank authority. Finally we would like to thank everybody who supported us in any respect for the completion of the thesis. It has been a marvelous experience to work with such an esteemed faculty to carry out this thesis under one of the most reputable engineering institution of Bangladesh. In perspective of power consumption in the sector of energy in Bangladesh the central air conditioning system is a desirable solution nowadays. The purpose of this thesis is to design a central air conditioning system for Military Institute of Science and Technology (MIST) tower building-2. The suggested design includes cooling load calculation, duct design and the specification of system components (chiller, air handling unit etc.). The cooling load is calculated for individual classrooms, laboratories and departmental offices. The selection of ducting system consists of duct diameter, friction loss, air flow velocity and air flow rate passing through the ducts. The central air conditioning system will maintain a constant air temperature desired for human comfort for a defined space. This system can be efficiently maintained rather than a split or individual one. We are hoping that, this design will be productive for MIST in case of cost effectiveness and power consumption. 2019-03-13T04:21:07Z 2019-03-13T04:21:07Z 2017-01 Thesis http://hdl.handle.net/123456789/430 en application/pdf DEPARTMENT OF MECHANICAL ENGINEERING MILITARY INSTITUTE OF SCIENCE AND TECHNOLOGY MIRPUR CANTONMENT, DHAKA - 1216, BANGLADESH
spellingShingle Noman, Mashruf Ahmad
Rafique, Maimuna Torsa
Toma, Prionkari Banik
DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title_full DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title_fullStr DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title_full_unstemmed DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title_short DESIGN OF CENTRAL AIR CONDITIONING SYSTEM FOR MIST TOWER BUILDING-2
title_sort design of central air conditioning system for mist tower building 2
url http://hdl.handle.net/123456789/430
work_keys_str_mv AT nomanmashrufahmad designofcentralairconditioningsystemformisttowerbuilding2
AT rafiquemaimunatorsa designofcentralairconditioningsystemformisttowerbuilding2
AT tomaprionkaribanik designofcentralairconditioningsystemformisttowerbuilding2